Heat circuit
Endpoint group client.heat_circuit (HeatCircuitEndpoints).
API Endpoints to send and retrieve the heat circuit data.
Example
client = KebaKeEnergyAPI(
host="ap4400.local",
username="test",
password="test",
ssl=True,
skip_ssl_verification=True
)
await client.heat_circuit.get_name()
get_name
async def get_name(position: int = 1) -> str
Get the heat circuit name.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
str: Heat circuit name
get_mode
async def get_mode(position: int = 1, *, human_readable: bool = True) -> int | str
Get the mode from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: 0 (HEATING) / 1 (COOLING) / 2 (HEATING_AND_COOLING) / 3 (HEATING_AND_ACTIVE_COOLING)
has_room_temperature
async def has_room_temperature(position: int = 1, *, human_readable: bool = True) -> int | str
Check if room temperature from the heat circuit is available.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: 0 (OFF) / 1 (ON)
get_room_temperature
async def get_room_temperature(position: int = 1) -> float
Get the room temperature from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
has_room_humidity
async def has_room_humidity(position: int = 1, *, human_readable: bool = True) -> int | str
Check if room humidity from the heat circuit is available.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: 0 (OFF) / 1 (ON)
get_room_humidity
async def get_room_humidity(position: int = 1) -> float
Get the room humidity from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Humidity in percent
get_dew_point
async def get_dew_point(position: int = 1) -> float
Get the dew point from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
get_flow_temperature_setpoint
async def get_flow_temperature_setpoint(position: int = 1) -> float
Get the flow temperature setpoint from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
has_mixer
async def has_mixer(position: int = 1, *, human_readable: bool = True) -> int | str
Check if heating circuit mixer is available.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: 0 (OFF) / 1 (ON)
get_mixer_flow_temperature
async def get_mixer_flow_temperature(position: int = 1) -> float
Get the mixer flow temperature from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
get_mixer_return_flow_temperature
async def get_mixer_return_flow_temperature(position: int = 1) -> float
Get the mixer return flow temperature from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
get_mixer_position
async def get_mixer_position(position: int = 1, *, human_readable: bool = True) -> int | str
Get the mixer position.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: -1 (CLOSED) / 0 (OFF) / 1 (OPEN)
get_pump_state
async def get_pump_state(position: int = 1, *, human_readable: bool = True) -> int | str
Get the pump state.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: 0 (OFF) / 1 (ON)
has_return_flow_temperature
async def has_return_flow_temperature(
position: int = 1,
*,
human_readable: bool = True,
) -> int | str
Check if the return flow temperature sensor is available.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: 0 (OFF) / 1 (ON)
get_return_flow_temperature
async def get_return_flow_temperature(position: int = 1) -> float
Get the return flow temperature from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
get_target_temperature
async def get_target_temperature(position: int = 1) -> float
Get the target temperature from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
get_use_excess_energy
async def get_use_excess_energy(position: int = 1, *, human_readable: bool = True) -> int | str
Get the use excess energy state.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: (0) OFF / (1) ON
set_use_excess_energy
async def set_use_excess_energy(mode: int | str, position: int = 1) -> None
Set the use excess energy.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- mode
int | str: Set the mode as integer or string (human-readable) e.g. 0 or OFF - position
int(default:1): Position of the heating circuit, starting at 1
get_excess_energy_mode
async def get_excess_energy_mode(position: int = 1, *, human_readable: bool = True) -> int | str
Get the excess energy mode.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: (0) OFF / (1) HEATING / (2) COOLING
get_excess_energy_target_temperature
async def get_excess_energy_target_temperature(position: int = 1) -> float
Get the excess energy target temperature from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_excess_energy_target_temperature
async def set_excess_energy_target_temperature(temperature: float, position: int = 1) -> None
Set the excess energy target temperature from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The excess energy target temperature for the day in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_excess_energy_target_temperature_hysteresis
async def get_excess_energy_target_temperature_hysteresis(position: int = 1) -> float
Get the excess energy target temperature hysteresis from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_excess_energy_target_temperature_hysteresis
async def set_excess_energy_target_temperature_hysteresis(
temperature: float,
position: int = 1,
) -> None
Set the excess energy target temperature hysteresis from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The excess energy target temperature in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_excess_energy_target_cooling_temperature
async def get_excess_energy_target_cooling_temperature(position: int = 1) -> float
Get the excess energy target cooling temperature from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_excess_energy_target_cooling_temperature
async def set_excess_energy_target_cooling_temperature(
temperature: float,
position: int = 1,
) -> None
Set the excess energy target cooling temperature from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The excess energy target cooling temperature for the day in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_excess_energy_target_cooling_temperature_hysteresis
async def get_excess_energy_target_cooling_temperature_hysteresis(position: int = 1) -> float
Get the excess energy target cooling temperature hysteresis from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_excess_energy_target_cooling_temperature_hysteresis
async def set_excess_energy_target_cooling_temperature_hysteresis(
temperature: float,
position: int = 1,
) -> None
Set the excess energy target cooling temperature hysteresis from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The excess energy target cooling temperature in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_selected_target_temperature
async def get_selected_target_temperature(position: int = 1) -> float
Get the selected target temperature from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
get_target_temperature_day
async def get_target_temperature_day(position: int = 1) -> float
Get the target temperature for the day from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_target_temperature_day
async def set_target_temperature_day(temperature: float, position: int = 1) -> None
Set the target temperature for the day from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The target temperature for the day in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_target_cooling_temperature_day
async def get_target_cooling_temperature_day(position: int = 1) -> float
Get the target cooling temperature for the day from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_target_cooling_temperature_day
async def set_target_cooling_temperature_day(temperature: float, position: int = 1) -> None
Set the target cooling temperature for the day from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The target cooling temperature for the day in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_heating_limit_day
async def get_heating_limit_day(position: int = 1) -> float
Get the heating limit for the day from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_heating_limit_day
async def set_heating_limit_day(temperature: float, position: int = 1) -> None
Set the heating limit for the day from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The heating limit temperature for the day in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_cooling_limit_day
async def get_cooling_limit_day(position: int = 1) -> float
Get the cooling limit for the day from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_cooling_limit_day
async def set_cooling_limit_day(temperature: float, position: int = 1) -> None
Set the cooling limit for the day from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The cooling limit temperature for the day in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_excess_energy_heating_limit_day
async def get_excess_energy_heating_limit_day(position: int = 1) -> float
Get the excess energy heating limit for the day from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_excess_energy_heating_limit_day
async def set_excess_energy_heating_limit_day(temperature: float, position: int = 1) -> None
Set the excess energy heating limit for the day from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The excess energy heating limit temperature for the day in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_excess_energy_cooling_limit_day
async def get_excess_energy_cooling_limit_day(position: int = 1) -> float
Get the excess energy cooling limit for the day from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_excess_energy_cooling_limit_day
async def set_excess_energy_cooling_limit_day(temperature: float, position: int = 1) -> None
Set the excess energy cooling limit for the day from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The excess energy cooling limit temperature for the day in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_target_temperature_night
async def get_target_temperature_night(position: int = 1) -> float
Get the target temperature for the night from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_target_temperature_night
async def set_target_temperature_night(temperature: float, position: int = 1) -> None
Set the target temperature for the night from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The target temperature for the day in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_target_cooling_temperature_night
async def get_target_cooling_temperature_night(position: int = 1) -> float
Get the target cooling temperature for the night from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_target_cooling_temperature_night
async def set_target_cooling_temperature_night(temperature: float, position: int = 1) -> None
Set the target cooling temperature for the night from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The target cooling temperature for the day in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_heating_limit_night
async def get_heating_limit_night(position: int = 1) -> float
Get the heating limit for the night from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_heating_limit_night
async def set_heating_limit_night(temperature: float, position: int = 1) -> None
Set the heating limit for the night from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The heating limit temperature for the night in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_cooling_limit_night
async def get_cooling_limit_night(position: int = 1) -> float
Get the cooling limit for the night from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_cooling_limit_night
async def set_cooling_limit_night(temperature: float, position: int = 1) -> None
Set the cooling limit for the night from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The cooling limit temperature for the night in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_excess_energy_heating_limit_night
async def get_excess_energy_heating_limit_night(position: int = 1) -> float
Get the excess energy heating limit for the night from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_excess_energy_heating_limit_night
async def set_excess_energy_heating_limit_night(temperature: float, position: int = 1) -> None
Set the excess energy heating limit for the night from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The excess energy heating limit temperature for the night in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_excess_energy_cooling_limit_night
async def get_excess_energy_cooling_limit_night(position: int = 1) -> float
Get the excess energy cooling limit for the night from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_excess_energy_cooling_limit_night
async def set_excess_energy_cooling_limit_night(temperature: float, position: int = 1) -> None
Set the excess energy cooling limit for the night from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The excess energy cooling limit temperature for the night in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_target_temperature_away
async def get_target_temperature_away(position: int = 1) -> float
Get the target temperature when away for the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_target_temperature_away
async def set_target_temperature_away(temperature: float, position: int = 1) -> None
Set the target temperature when away for the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The target temperature for the day in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_target_temperature_offset
async def get_target_temperature_offset(position: int = 1) -> float
Get the target temperature offset from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Temperature in °C
set_target_temperature_offset
async def set_target_temperature_offset(offset: float, position: int = 1) -> None
Set the target temperature offset for the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- offset
float: The target temperature offset - position
int(default:1): Position of the heating circuit, starting at 1
get_operating_mode
async def get_operating_mode(position: int = 1, *, human_readable: bool = True) -> int | str
Get the operating mode from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: 0 (OFF) / 1 (AUTO) / (2) DAY / (3) NIGHT / (4) HOLIDAY / (5) PARTY / (8) EXTERNAL / (9) ROOM_CONTROL
set_operating_mode
async def set_operating_mode(mode: int | str, position: int = 1) -> None
Set the operating mode from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- mode
int | str: Set the mode as integer or string (human-readable) e.g. 0 or OFF - position
int(default:1): Position of the heating circuit, starting at 1
get_heat_request
async def get_heat_request(position: int = 1, *, human_readable: bool = True) -> int | str
Get the heat request state from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: 0 (OFF) / 1 (ON)
get_cool_request
async def get_cool_request(position: int = 1, *, human_readable: bool = True) -> int | str
Get the cool request state from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: 0 (OFF) / 1 (ON)
get_away_start_date
async def get_away_start_date(position: int = 1) -> int
Get the away start date from the heating circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
int: Start date as unix timestamp
set_away_start_date
async def set_away_start_date(timestamp: int, position: int = 1) -> None
Set the away start date from the heating circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- timestamp
int: Start date as unix timestamp - position
int(default:1): Position of the heating circuit, starting at 1
get_away_end_date
async def get_away_end_date(position: int = 1) -> int
Get the away end date from the heating circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
int: End date as unix timestamp
set_away_end_date
async def set_away_end_date(timestamp: int, position: int = 1) -> None
Set the away end date from the heating circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- timestamp
int: End date as unix timestamp - position
int(default:1): Position of the heating circuit, starting at 1
get_heating_curve_offset
async def get_heating_curve_offset(position: int = 1) -> float
Get the heating curve offset from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Offset in °C
set_heating_curve_offset
async def set_heating_curve_offset(offset: float, position: int = 1) -> None
Set the heating curve offset from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- offset
float: The offset in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_cooling_curve_offset
async def get_cooling_curve_offset(position: int = 1) -> float
Get the cooling curve offset from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Offset in °C
set_cooling_curve_offset
async def set_cooling_curve_offset(offset: float, position: int = 1) -> None
Set the cooling curve offset from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- offset
float: The offset in °C - position
int(default:1): Position of the heating circuit, starting at 1
get_heating_curve_slope
async def get_heating_curve_slope(position: int = 1) -> float
Get the heating curve slope from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Slope
set_heating_curve_slope
async def set_heating_curve_slope(slope: float, position: int = 1) -> None
Set the heating curve slope from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- slope
float: The slope - position
int(default:1): Position of the heating circuit, starting at 1
get_cooling_curve_slope
async def get_cooling_curve_slope(position: int = 1) -> float
Get the cooling curve slope from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Slope
set_cooling_curve_slope
async def set_cooling_curve_slope(slope: float, position: int = 1) -> None
Set the cooling curve slope from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- slope
float: The slope - position
int(default:1): Position of the heating circuit, starting at 1
get_use_heating_curve
async def get_use_heating_curve(position: int = 1, *, human_readable: bool = True) -> int | str
Get the use heating curve from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: (0) OFF / (1) ON
set_use_heating_curve
async def set_use_heating_curve(mode: int | str, position: int = 1) -> None
Set the use heating curve.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- mode
int | str: Set the mode as integer or string (human-readable) e.g. 0 or OFF - position
int(default:1): Position of the heating circuit, starting at 1
get_heating_curve
async def get_heating_curve(position: int = 1) -> str
Get the heating curve from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
str: Name of the heating curve, e.g. HC1
set_heating_curve
async def set_heating_curve(heating_curve: str, position: int = 1) -> None
Set the heating curve from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- heating_curve
str: The heating curve name, e.g. HC1 - position
int(default:1): Position of the heating circuit, starting at 1
get_cooling_curve
async def get_cooling_curve(position: int = 1) -> str
Get the cooling curve from the heat circuit.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
str: Name of the cooling curve, e.g. HC1
set_cooling_curve
async def set_cooling_curve(cooling_curve: str, position: int = 1) -> None
Set the cooling curve from the heat circuit.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- cooling_curve
str: The cooling curve name, e.g. HC2 - position
int(default:1): Position of the heating circuit, starting at 1
get_heating_curve_points
async def get_heating_curve_points(heating_curve: str | None = None) -> HeatingCurves
Get the heating curve points.
Parameters
- heating_curve
str | None(default:None): The heating curve name
Returns
HeatingCurves: One or more heating curves and the points
set_heating_curve_points
async def set_heating_curve_points(heating_curve: str, points: HeatingCurvePoints) -> None
Set the heating curve points.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- heating_curve
str: The heating curve name - points
HeatingCurvePoints: Heating curve points
Raises
APIError: The heating curve is invalid.
get_available_heating_curves
async def get_available_heating_curves() -> tuple[tuple[int, str], ...]
Get available heating curves.
Returns
tuple[tuple[int, str], ...]: Index and heating curve name pairs
has_pump
async def has_pump(position: int = 1, *, human_readable: bool = True) -> int | str
Check if the heating circuit pump is available.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: 0 (OFF) / 1 (ON)
has_var_speed_pump
async def has_var_speed_pump(position: int = 1, *, human_readable: bool = True) -> int | str
Check if the heating circuit pump has a variable speed.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: 0 (OFF) / 1 (ON)
get_pump_speed
async def get_pump_speed(position: int = 1) -> float
Get pump speed.
Parameters
- position
int(default:1): Position of the heating circuit, starting at 1
Returns
float: Pump speed as a fraction from 0 to 1 (1 = 100 %)