Hot water tank
Endpoint group client.hot_water_tank (HotWaterTankEndpoints).
API Endpoints to send and retrieve the hot water tank data.
Example
client = KebaKeEnergyAPI(
host="ap4400.local",
username="test",
password="test",
ssl=True,
skip_ssl_verification=True
)
await client.hot_water_tank.get_name()
get_name
async def get_name(position: int = 1) -> str
Get the hot water tank name.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1
Returns
str: Hot water tank name
get_current_temperature
async def get_current_temperature(position: int = 1) -> float
Get the current temperature from the hot water tank.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1
Returns
float: Temperature in °C
get_operating_mode
async def get_operating_mode(position: int = 1, *, human_readable: bool = True) -> int | str
Get the operating mode from the hot water tank.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: (0) OFF / (1) AUTO / (2) ON / (3) HEAT_UP
set_operating_mode
async def set_operating_mode(mode: int | str, position: int = 1) -> None
Set the operating mode from the hot water tank.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- mode
int | str: Set the mode as integer or string (human-readable) e.g. 0 or OFF - position
int(default:1): Position of the hot water tank, starting at 1
get_min_target_temperature
async def get_min_target_temperature(position: int = 1) -> int
Get the minimum target temperature from the hot water tank.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1
Returns
int: Temperature in °C
get_max_target_temperature
async def get_max_target_temperature(position: int = 1) -> int
Get the maximum target temperature from the hot water tank.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1
Returns
int: Temperature in °C
get_standby_temperature
async def get_standby_temperature(position: int = 1) -> float
Get the standby temperature from the hot water tank.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1
Returns
float: Temperature in °C
set_standby_temperature
async def set_standby_temperature(temperature: float, position: int = 1) -> None
Set the standby temperature from the hot water tank.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The standby temperature in °C - position
int(default:1): Position of the hot water tank, starting at 1
get_target_temperature
async def get_target_temperature(position: int = 1) -> float
Get the target temperature from the hot water tank.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1
Returns
float: Temperature in °C
set_target_temperature
async def set_target_temperature(temperature: float, position: int = 1) -> None
Set the target temperature from the hot water tank.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The target temperature in °C - position
int(default:1): Position of the hot water tank, starting at 1
get_excess_energy_target_temperature
async def get_excess_energy_target_temperature(position: int = 1) -> float
Get the excess energy target temperature from the hot water tank.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1
Returns
float: Temperature in °C
set_excess_energy_target_temperature
async def set_excess_energy_target_temperature(temperature: float, position: int = 1) -> None
Set the excess energy target temperature from the hot water tank.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The excess energy target temperature in °C - position
int(default:1): Position of the hot water tank, starting at 1
get_excess_energy_target_temperature_hysteresis
async def get_excess_energy_target_temperature_hysteresis(position: int = 1) -> float
Get the excess energy target temperature hysteresis from the hot water tank.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1
Returns
float: Temperature in °C
set_excess_energy_target_temperature_hysteresis
async def set_excess_energy_target_temperature_hysteresis(
temperature: float,
position: int = 1,
) -> None
Set the excess energy target temperature hysteresis from the hot water tank.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- temperature
float: The excess energy target temperature in °C - position
int(default:1): Position of the hot water tank, starting at 1
get_use_excess_energy
async def get_use_excess_energy(position: int = 1, *, human_readable: bool = True) -> int | str
Get the use excess energy state.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: (0) OFF / (1) ON
set_use_excess_energy
async def set_use_excess_energy(mode: int | str, position: int = 1) -> None
Set the use excess energy.
Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.
Parameters
- mode
int | str: Set the mode as integer or string (human-readable) e.g. 0 or OFF - position
int(default:1): Position of the hot water tank, starting at 1
get_excess_energy_mode
async def get_excess_energy_mode(position: int = 1, *, human_readable: bool = True) -> int | str
Get the excess energy mode.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: (0) OFF / (1) HEATING / (2) COOLING
get_heat_request
async def get_heat_request(position: int = 1, *, human_readable: bool = True) -> int | str
Get the heat request state from the hot water tank.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: 0 (OFF) / 1 (ON)
has_fresh_water_module
async def has_fresh_water_module(position: int = 1, *, human_readable: bool = True) -> int | str
Check if fresh water module is available.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: 0 (OFF) / 1 (ON)
get_fresh_water_flow
async def get_fresh_water_flow(position: int = 1, *, human_readable: bool = True) -> int | str
Get the fresh water flow from the fresh water module.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: 0 (OFF) / 1 (ON)
get_fresh_water_module_temperature
async def get_fresh_water_module_temperature(position: int = 1) -> float
Get the fresh water module temperature.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1
Returns
float: Temperature in °C
get_fresh_water_module_pump_speed
async def get_fresh_water_module_pump_speed(position: int = 1) -> float
Get the fresh water module pump speed.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1
Returns
float: Pump speed as a fraction from 0 to 1 (1 = 100 %)
get_circulation_return_temperature
async def get_circulation_return_temperature(position: int = 1) -> float
Get the circulation return temperature.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1
Returns
float: Temperature in °C
get_circulation_pump_state
async def get_circulation_pump_state(position: int = 1, *, human_readable: bool = True) -> int | str
Get the circulation pump state.
Parameters
- position
int(default:1): Position of the hot water tank, starting at 1 - human_readable
bool(default:True): Return a human-readable string
Returns
int | str: 0 (OFF) / 1 (ON)